Pular para o conteúdo principal

Updating Lacuna PSC on Windows Server

To update your on-premises installation of Lacuna PSC on Windows Server, follow the steps below.

note

To see if an update will require changing any settings, look in the Lacuna PSC changelog for the changes between the version you are installing and the version you currently have installed (to know how to check the installed version, see this article).

  1. Stop the web site in IIS Manager.
  2. Create a backup of the database and of the site folder (by default, C:\inetpub\LacunaPsc).
  3. Extract the contents of the new package (psc-1.7.5.zip) to the site folder, overwriting all files. The package overwrites web.config, so re-apply any customization you made to it (your backup has the previous copy).
  4. If the changelog lists any configuration changes for the versions you are skipping, apply them to your settings file.
  5. Start the web site in IIS Manager.
note

The settings of your instance are kept in the file appsettings.ini, in the folder Lacuna Software\PSC inside the Windows common application data folder (by default, C:\ProgramData\Lacuna Software\PSC\appsettings.ini). This file is not part of the package, so it is preserved by the update.

note

If the new version updates the database model, the database is updated automatically when the application starts, unless you run Lacuna PSC without db_owner privileges. In that case, run the update-db command before starting the site.

See also​

View as Markdown